Silicone Rubber Insulated Power Cable

1.jpg


    1) Max. Working temperature in normal use: 180℃
1. Application
This product is used as power supply connection cables of electrical equipment in harsh environment such as port, power generation, metallurgical, petrochemical industry, etc. It can also be used in fixed power transmission lines.

2. Guide to Use

    2) Rated voltage U0/U: 600/1000V

    3) Min. ambient temperature: -60℃ for fixed installation and -20 for portable application.

4) Min. bend radius: 4 times cable diameter

3. Technical Performance

                Sectional Area (mm)

                    Max. Conductor DC Resistance at 20

                    (Ω/kM)

                Technical Parameters
                Tinned Copper                Plain Copper

Max. Insulation DC Resistance at 20

(MΩ·kM)

                Heat-proof Testing                Test Voltage
                4.0                4.95                5.09                0.210                After a heat test of 120h with 200±2℃ temperature, cool the cable for 4 hours, no crack in the insulation can be seen by bare eyes                3.5kV/5Min Voltage test, No breakdown occurs
                6.0                3.30                3.39
                10.0                1.911.95
                16.0                1.21                1.24
                25.0                0.780                0.795
                35.0                0.554                0.565
                50.0                0.386                0.393
                70.0                0.272                0.277                35
                95.0                0.206                0.210
                Flame-retardant Performance                Comply with GB 12666.5 with an oxygen index over 28, exceed requirements of Class B


4. Code and Description

                Code                Description
                DHTGGR                Copper core silicone rubber insulation and sheath flexible cable
                DHTGGRxTinning copper core silicone rubber insulation and sheath flexible cable
                DHTFGR                Copper core fluorine plastic insulation silicone rubber sheath flexible cable
                DHTFGRx                Tinning copper core fluorine plastic insulation silicone rubber sheath flexible cable
                DHTGVtR                Copper core silicane rubber insulation elastomer sheath flexible cable
                DHTGVtRx                Tinning copper core silicone rubber insulation plastic elastomer sheath flexible cable
                DHTGGRP                Copper core silicone rubber insulation and sheath copper wire knitting shield flexible cable
                DHTGVtR22                Copper core silicone rubber insulation plastic elastomer sheath steel tape armor cable


5. Technical Particulars
1) 2 Cores

                No. of Cores * Sectional Area
(mm2)
                Conductor Strands/Dia.                Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

                (mm)
                2*4                19/0.52                12.5                194.0
                2*6                19/0.63                16.2                330.0
                2*10                37/0.58                21.2                390.0
                2*16                119/0.41                23.5                670.0
                2*25                98/0.58                27.0                984.0
                2*35                133/0.58                31.4                1276.0
                2*50189/0.58                36.5                1770.0
                2*70                366/0.52                41.4                2273.0
                2*95                448/0.52                46.8                3051.0


    2) 3 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

(mm)
                3*4                19/0.52                14.0                217
                3*6                19/0.63                17.0                373.0
                3*10                37/0.58                22.7                665.0
                3*16                119/0.41                24.5                890.0
                3*25                98/0.58                28.6                1351.0
                3*35                133/0.58                32.6                1744.0
                3*50                198/0.58                38.1                2357.0
                3*70                366/0.52                43.2                3140.0
                3*95                448/0.52                49.6                4224.0


    3) 4 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

(mm)
                4*4                19/0.52                15.1                334.0
                4*6                19/0.63                18.1                483.0
                4*10                37/0.58                23.7                838.0
                4*16                119/0.41                26.0                1137.0
                4*25                98/0.58                32.1                1750.0
                4*35                133/0.58                36.1                2258.0
                4*50                189/0.58                42.2                3052.2
4*70                366/0.52                45.7                3932.0
                4*95                448/0.52                54.3                5431.0


4) 5 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

(mm)
                5*4                19/0.52                16.0                415.0
                5*6                19/0.63                20.1                598.0
                5*10                37/0.58                26.1                1026.0
                5*16                119/0.41                29.7                1410.0
                5*25                98/0.58                35.5                2159.0
                5*35                133/0.58                39.3                2709.0
                5*50                189/0.58                44.5                3638.0
                5*70                366/0.52                50.2                4827.0
                5*95                448/0.52                59.5                6659.0


    5) 3+1 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

(mm)
                3 4+1 2.5                19/0.52+19/0.41                15.1                325.0
                3 6+1 4                19/0.63+19/0.52                18.1                460.0
                3 10+1 6                37/0.58+19/0.63                23.7                805.0
                3 16+1 10                119/0.41+37/0.58                26.0                1087.0
                3 25+1 16                98/0.58+119/0.41                32.1                1670.0
                3 35+1 16                133/0.58+119/0.41                36.1                2087.0
                3 50+1 25                189/0.58+98/0.58                42.2                2827.0
                3 70+1 35                366/0.52+133/0.58                45.7                3617.0
                3 95+1 50                448/0.52+189/0.58                54.3                5026


    6) 3+2 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                    Approx. Weight

(kg/km)

(mm)
                3*4+2*2.5                19/0.52+19/0.41                16.0                388.0
                3*6+2*4                19/0.63+19/0.52                20.1                562.0
                3*10+2*6                37/0.58+19/0.63                26.1                954.0
                3*16+2*10                119/0.41+37/0.58                29.7                1302.0
                3*25+2*16                98/0.58+119/0.41                35.5                1997.0
                3*35+2*16                133/0.58+119/0.41                39.3                2367.0
                3*50+2*25                189/0.58+98/0.58                44.5                3188.0
                3*70+2*35                366/0.52+133/0.58                50.2                4197.0
                3*95+2*50                448/0.52+189/0.58                59.5                5849.0


        7) 4+1 Cores

No. of Cores * Sectional Area
(mm2)
Conductor Strands/Dia.Overall Dia.
(mm)

                        Approx. Weight

(kg/km)

(mm)
                    4*4+1*2.5                    19/0.52+19/0.41                    16.0                    400.0
                    4*6+1*4                    19/0.63+19/0.52                    20.1                    580.0
                    4*10+1*6                    37/0.58+19/0.63                    26.1                    990.0
                    4*16+1*10                    119/0.41+37/0.58                    29.7                    1356.0
                    4*25+1*16                    98/0.58+119/0.41                    35.5                    2078.0
                    4*35+1*16                    133/0.58+119/0.41                    39.3                    2538.0
                    4*50+1*25                    189/0.58+98/0.58                    44.5                    3413.0
                    4*70+1*35                    366/0.52+133/0.58                    50.2                    4512.0
                    4*95+1*50                    448/0.52+189/0.58                    59.5                    6245.0

Contact us

Add:No.268 jingwu road, economic development zone,
   yueqing city, zhejiang province
Service hotline:400-0700-118  Tel:0577-62667555
Alibaba site:zghongqidianlan.1688.com
© 2013-2018 China · HongQi group LTD. All rights reserved

  • Company website

  • Enter Alibaba

© 2013-2018 China · HongQi group LTD. All rights reserved