1. Standard
JB 8734.3-2012: PVC Insulated Cables and Flexible Cores of Rated Voltage 450/750V and Below
2. Application
This product is used for household electrical appliances, instruments & meters and lighting of rated voltage up to and including 300/300V.
3. Guide to Use
Max. conductor temperature in normal use: 70℃
4. Code, Description and Specifications
Code | Description | Rated Voltage (V) | No. of Cores | Sectional Area (mm2) |
RVS | PVC Insulated non-sheathed twisted flexible cord | 300/300 | 2 | 0.5~0.75 |
5. Technical Particulars
No. of Cores * Sectional Area (mm2) | Max. Diameter of Individual Wire (mm) | Insulation Thickness (mm) | Max. Overall Diameter (mm) | Max. Conductor DC Resistance at 20℃ (Ω/kM) | Min. Insulation Resistance (Ω/km) | |
Plain Copper | Tinned Copper | |||||
2*0.5 | 0.16 | 0.8 | 6.0 | 39.0 | 40.1 | 0.016 |
2*0.75 | 0.16 | 0.8 | 6.2 | 26.0 | 26.7 | 0.014 |
2*10 | 0.16 | 0.8 | 6.6 | 19.5 | 20.0 | 0.011 |
2*1.5 | 0.16 | 0.8 | 7.2 | 13.3 | 13.7 | 0.010 |
2*2.5 | 0.16 | 0.8 | 8.2 | 7.98 | 8.21 | 0.009 |
2*4 | 0.16 | 0.8 | 9.2 | 4.95 | 5.09 | 0.007 |
2*6 | 0.21 | 1.0 | 10.6 | 3.30 | 3.39 | 0.006 |
Add:No.268 jingwu road, economic development zone,