CN

Flame-retardant Rubber Sheathed Cables for Mining Purposes

Rubber Sheathed Flexible Cable with Metallic Screen and Monitoring Core of Rated Voltage 8.7/10kV and below

1.jpg

1. Application

This product is used as power supply connection cable for portable mining equipment or similar devices of rated voltage 8.7/10kV and below.


2. Guide to Use

Max. conductor temperature in normal use is 90℃ and the min. bend radius is 6 times cable diameter.  Cables with yellow sheath are not allowed to be exposed to sunlight for a long time.


3. Code, Description and Usage

Code Description Usage
MYPTJ-3.6/6 Flexible rubber-sheathed cables with
individual metallic screen and monitoring core for mining use
Power supply connection cable for 3.6/6kV portable mining equipment or similar devices
MYPTJ-6/10Power supply connection cable for 6/10kV portable mining equipment or similar devices
MYDTJ-8.7/10Power supply connection cable for 8.7/10kV portable mining equipment or similar devices


4. Sectional Drawing

2.jpg


5. Technical Particulars

1) MYPTJ-3.6/6

No. of Cores * Sectional Area (mm2) Nominal Thickness (mm2) Overall Diameter (mm)
Power Core Earth Core Monitoring Core Power Core Insulation Inner Sheath Outer Sheath MYPTJ-3.6/6
3*25 3*16/3 3*2.5 4.0 2.5 5.5 61.0-69.0
3*35 3*16/3 3*2.5 4.0 2.5 5.5 63.5-72.0
3*50 3*16/3 3*2.5 4.0 2.5 5.5 67.5-76.0
3*70 3*25/3 3*2.5 4.0 3.0 5.5 72.5-82.0
3*95 3*35/3 3*2.5 4.0 3.0 5.5 77.0-87.0
3*120 3*35/3 3*2.5 4.0 3.0 5.5 80.5-90.0
3*150 3*50/3 3*2.5 4.0 3.0 5.5 84.5-94.5


2) MYPTJ-6/10

No. of Cores * Sectional Area (mm2) Nominal Thickness (mm2) Overall Diameter (mm)
Power Core Earth Core Monitoring Core Power Core Insulation Inner Sheath Outer Sheath MYPTJ-6/10
3*25 3*16/3 3*2.5 4.5 2.5 5.5 63.0-71.0
3*35 3*16/3 3*2.5 4.5 2.5 5.5 66.0-74.5
3*50 3*16/3 3*2.5 4.5 2.5 5.5 70.5-79.5
3*70 3*25/3 3*2.5 4.5 3.0 5.5 74.5-84.0
3*95 3*35/3 3*2.5 4.5 3.0 5.5 79.5-88.5
3*120 3*35/3 3*2.5 4.5 3.0 5.5 82.5-92.0
3*150 3*50/3 3*2.5 4.5 3.0 5.5 86.5-96.5


3) MYPTJ-8.7/10

No. of Cores * Sectional Area (mm2) Nominal Thickness (mm2) Overall Diameter (mm)
Power Core Earth Core Monitoring Core Power Core Insulation Inner Sheath Outer Sheath MYPTJ-8.7/10
3*25 3*16/3 3*2.5 5.5 2.5 5.5 67.0-76.0
3*35 3*16/3 3*2.5 5.5 2.5 5.5 71.0-80.0
3*50 3*16/3 3*2.5 5.5 2.5 5.5 75.0-84.5
3*70 3*25/3 3*2.5 5.5 3.0 5.5 79.0-88.0
3*95 3*35/3 3*2.5 5.5 3.0 5.5 83.5-93.0
3*120 3*35/3 3*2.5 5.5 3.0 5.5 86.5-96.5
3*150 3*50/3 3*2.5 5.5 3.0 5.5 91.0-101.5


6. Technical Performance
1) Conductor Resistance

Power Core Sectional Area (mm2) Conductor DC Resistance at 20℃ (Ω/km)Power Core Sectional Area (mm2)Conductor DC Resistance at 20℃ (Ω/km)
25 ≤0.795 95 ≤0.210
35 ≤0.565 120 ≤0.164
50 ≤0.393 150 ≤0.132
70 ≤0.277    


2) Insulation Resistance

Power Core Sectional Area (mm2) Insulation DC Resistance at 20℃ (MΩ·kM)
Rated Voltage 3.6/6kV Rated Voltage 6/10kV Rated Voltage 8.7/10kV
25 ≥650 ≥700 ≥1250
35 ≥550 ≥650 ≥1150
50 ≥500 ≥550 ≥1000
70 ≥450 ≥500 ≥900
95 ≥400 ≥450 ≥800
120 ≥350 ≥400 ≥750
150 ≥350 ≥350 ≥700


3) Max. conductor temperature in normal use: 90℃.
4) Insulation tensile strength is over 6.5MPa, and has an elongation of over 200% at break.
5) Sheath tensile strength is over 11.0MPa, and has an elongation of over 250% at break.
6) 0.38/0.66kV cables can withstand a 3.0kV/5Min voltage test and no breakdown shall occur; 0.66/1.14kV cables can withstand a 3.7kV/5Min voltage test and no breakdown shall occur.
7) The flame-retardant performance of the cable meets all requirements of burn test in standard MT 386-1995.

Contact us

Add:No.268 jingwu road, economic development zone,
   yueqing city, zhejiang province
Service hotline:400-0700-118  Tel:0577-62667555
Alibaba site:zghongqidianlan.1688.com
© 2013-2018 China · HongQi group LTD. All rights reserved

  • Company website

  • Enter Alibaba

© 2013-2018 China · HongQi group LTD. All rights reserved