1. Application
This product is used as power supply connection cable for coal cutters or similar equipment of rated voltage 1.9/3.3kV and below.
2. Guide to Use
The max. conductor temperature in normal use is 90℃ and the min. bend radius of the cables is 6 times cable diameter.
3. Code, Description and Usage
Code | Description | Usage |
MCPT-1.9/3.3 | 1.9/3.3kV flexible coal cutter cable with individual metallic screen | Power supply connection cable for 1.9/3.3kV coal cutters and similar equipment |
MCPTJ1.9/3.3 | 1.9/3.3kV flexible coal cutter cable with individual metallic screen and monitoring core | Power supply connection cable for 1.9/3.3kV coal cutters and similar equipment |
MCPTJ-0.66/1.14 | 0.66/1.14kV flexible coal cutter cable with individual metallic screen and monitoring core | Power supply connection cable for 0.66/1.14kV coal cutters and similar equipment |
4. Sectional Drawing
5. Technical Parameters
1) MCPT-0.66/1.14, MCPTJ-0.66/1.14
No. of Cores * Sectional Area (mm2) | Nominal Thickness (mm) | Overall Diameter (mm) | |||||
Power Core | Ground Core | Control Core | Auxiliary Core | Power Core Insulation (mm) | Sheath (mm) | MCPT-0.66/1.14 | MCPTJ-0.66/1.14 |
3*25 | 1*16 | 3*4 | 1*16 | 1.6 | 5.0 | 39.7-42.9 | 39.7-42.9 |
3*35 | 1*16 | 3*4 | 1*16 | 1.6 | 5.0 | 43.1-46.3 | 43.4-46.3 |
3*50 | 1*25 | 3*4 | 1*25 | 1.7 | 5.3 | 48.5-51.8 | 48.5-51.8 |
3*70 | 1*35 | 3*6 | 1*35 | 1.8 | 5.8 | 55.1-58.8 | 15.1-58.8 |
3*95 | 1*50 | 3*6 | 1*50 | 2.0 | 6.4 | 62.4-66.1 | 62.4-66.1 |
3*120 | 1*50 | 3*10 | 1*70 | 2.2 | 6.9 | 68.0-72.5 | 68.0-72.5 |
3*150 | 1*70 | 3*10 | 1*70 | 2.4 | 7.3 | 74.5-79.5 | 74.5-79.5 |
Note: the outer diameter of monitoring core shall be the same as that of the power core
2) MCPJB-0.66/1.14
No. of Cores * Sectional Area (mm2) | Nominal Thickness (mm) | Overall Diameter (mm) | |||
Power Core | Ground Core | Control Core | Power Core Insulation (mm) | Sheath (mm) | MCPJB-0.66/1.14 |
3*25 | 1*16 | 1*16 | 1.6 | 5.1 | 47.4-49.9 |
3*35 | 1*16 | 1*16 | 1.6 | 5.5 | 51.6-54.6 |
3*50 | 1*25 | 1*25 | 1.7 | 5.9 | 56.8-59.8 |
3*70 | 1*35 | 1*35 | 1.8 | 6.4 | 62.8-67.8 |
3*95 | 1*50 | 1*50 | 2.0 | 6.9 | 68.9-72.7 |
3*120 | 1*50 | 1*70 | 2.2 | 7.3 | 73.4-77.2 |
3*130 | 1*70 | 1*70 | 2.4 | 7.8 | 79.0-83.6 |
Note: the outer diameter of monitoring core shall be the same as that of the power core
3) MCPJB-0.66/1.14
No. of Cores * Sectional Area (mm2) | Nominal Thickness (mm2) | Overall Diameter (mm) | |||
Power Core | Ground Core | Control Core | Power Core Insulation (mm) | Sheath (mm) | MCPJB-0.66/1.14 |
3*25 | 1*16 | 3*4 | 3.0 | 5.1 | 47.4-49.9 |
3*35 | 1*16 | 3*4 | 3.0 | 5.5 | 51.6-54.6 |
3*50 | 1*25 | 3*4 | 3.0 | 5.9 | 56.8-59.8 |
3*70 | 1*35 | 3*6 | 3.0 | 6.4 | 62.8-67.8 |
3*95 | 1*50 | 3*6 | 3.0 | 6.9 | 68.9-72.7 |
3*120 | 1*50 | 3*10 | 3.0 | 7.3 | 73.4-77.2 |
3*130 | 1*70 | 3*10 | 3.0 | 7.8 | 79.0-83.6 |
Note: the outer diameter of monitoring core shall be the same as that of the power core
6. Technical Performance
1) The conductor resistance meets the following requirements
Power Core Sectional Area (mm2) | Conductor DC resistance at 20℃ (Ω/kM) | Power Core Sectional Area (mm2) | Conductor DC resistance at 20℃ (Ω/kM) |
16 | ≤1.24 | 50 | ≤0.393 |
25 | ≤0.795 | 70 | ≤0.277 |
35 | ≤0.565 | 95 | ≤0.210 |
120 | ≤0.164 | 150 | ≤0.132 |
2) The insulation resistance meets the following requirements
Power Core Sectional Area (mm2) | Insulation Resistance at 20℃ (MΩ·kM) | ||
0.66/1.15 KV | 1.9/3.3 KV | ||
16 |
≥350 | - | |
26 | ≥350 | - | |
35 | ≥300 | ≥400 | |
50 | ≥250 | ≥350 | |
70 | ≥250 | ≥300 | |
95 | ≥200 | ≥250 | |
120 | ≥200 | ≥250 | |
150 | ≥180 | ≥250 | |
Control Core | 4/6/10 | ≥100 | ≥100 |
3) Max. conductor temperature in normal use: 90℃.
4) Insulation tensile strength is over 6.5MPa, and has an elongation of over 200% at break.
5) Sheath tensile strength is over 11.0MPa, and has an elongation of over 250% at break.
6) 0.38/0.66kV cables can withstand a 3.0kV/5Min voltage test and no breakdown shall occur; 0.66/1.14kV cables can withstand a 3.7kV/5Min voltage test and no breakdown shall occur.
7) The flame-retardant performance of the cable meets all requirements of burn test in standard MT 386-1995.
Add:No.268 jingwu road, economic development zone,
yueqing city, zhejiang province
Service hotline:400-0700-118 Tel:0577-62667555
Alibaba site:zghongqidianlan.1688.com
© 2013-2018 China · HongQi group LTD. All rights reserved