1. Standard
JB 6213.2-1992
2. Application
This product is used as connecting wire of electric motor with Class B insulation of rated voltage 1140V and below as well as the electrical winding. It is also used as leading wire of poles of the shell or winding.
3. Code and Description
JXN/JBQ: Rubber insulated and NBR sheathed leading wire 1) Tinned copper conductor 2) Separator (if any) 3) Rubber insulation 4) NBR sheath Note: This product can be black, white, green, red and other various bright colors with a long duration. |
4. Technical Parameters
JXN/JBQ: 500V
Sectional Area (mm2) | Conductor (mm) | Nominal Insulation Thickness (mm) | Nominal Sheath Thickness (mm) | Max. Overall Dia. (mm) | Approx. Weight (kg/km) | Max. conductor DC resistance at 20℃ (Ω/km) | |
Strands | Dia. (mm) | ||||||
0.5 | 28 | 0.15 | 0.6 | 0.8 |
4.3 | 20 | 38.5 |
0.75 | 42 | 0.15 | 0.6 | 0.8 | 4.5 | 24 | 25.7 |
1.0 | 32 | 0.20 | 0.6 | 0.8 | 4.7 | 28 | 18.9 |
1.5 | 48 | 0.20 | 0.6 | 0.8 | 5.0 | 35 | 12.6 |
2.5 | 19 | 0.41 | 0.8 | 1.0 | 6.2 | 57 | 7.59 |
4 |
19 | 0.52 | 0.8 | 1.0 | 6.8 | 76 | 4.54 |
6 | 19 | 0.64 | 0.8 | 1.0 | 7.5 | 100 | 3.00 |
10 | 49 |
0.52 | 1.0 | 1.2 | 10.0 | 178 | 1.78 |
16 | 49 | 0.64 | 1.0 | 1.2 | 11.2 | 243 | 1.18 |
25 | 98 | 0.58 | 1.0 | 1.4 | 13.7 | 372 | 0.716 |
35 | 133 | 0.58 | 1.0 | 1.4 | 14.9 | 471 | 0.528 |
50 | 133 | 0.68 | 1.2 | 1.6 | 17.1 | 647 | 0.384 |
70 | 189 | 0.68 | 1.2 | 1.6 | 19.6 | 876 | 0.270 |
95 | 259 | 0.68 | 1.4 | 1.6 | 21.9 | 1160 | 0.197 |
120 | 259 | 0.76 | 1.6 | 1.8 | 24.6 | 1451 | 0.158 |
150 | 320 | 0.76 | 1.8 | 2.2 | 29 | 1911.5 | 0.132 |
185 | 395 | 0.76 | 1.8 | 2.2 | 32 | 2268.65 | 0.108 |
240 | 513 | 0.76 | 2.2 | 3 | 35 | 3010 | 0.0817 |
300 | 641 | 0.76 | 2.4 | 3.5 | 38 | 3770 | 0.0654 |
JXN/JBQ: 1140V
Sectional Area (mm2) | Conductor (mm) | Nominal Insulation Thickness (mm) | Nominal Sheath Thickness (mm) | Max. Overall Dia. (mm) | Approx. Weight (kg/km) | Max. conductor DC resistance at 20℃ (Ω/km) | |
Strands | Dia. (mm) | ||||||
0.5 | 28 | 0.15 | 1.0 | 0.8 | 5.1 | 29 | 38.5 |
0.75 | 42 | 0.15 | 1.0 |
0.8 | 5.4 | 33 | 25.7 |
1.0 | 32 | 0.20 | 1.0 | 0.8 | 5.5 | 37 | 18.9 |
1.5 |
48 | 0.20 | 1.0 | 0.8 | 5.9 | 44 | 12.6 |
2.5 | 19 | 0.41 | 1.2 | 1.0 | 7.1 | 69 | 7.59 |
4 |
19 | 0.52 |
1.2 | 1.0 | 7.7 | 89 | 4.54 |
6 | 19 | 0.64 | 1.2 | 1.0 | 8.4 | 115 | 3.00 |
10 | 49 | 0.58 | 1.4 | 1.2 | 10.9 | 197 | 1.78 |
16 | 49 | 0.64 | 1.4 | 1.2 | 12.0 |
264 | 1.18 |
25 | 98 | 0.58 | 1.4 | 1.4 | 14.6 | 398 | 0.716 |
35 | 133 | 0.58 | 1.4 | 1.4 | 15.7 | 499 | 0.528 |
50 | 133 | 0.68 | 1.6 | 1.6 | 17.9 | 679 | 0.384 |
70 | 189 | 0.68 | 1.6 | 1.6 | 20.5 |
914 | 0.270 |
95 | 259 | 0.68 | 1.8 | 1.6 | 22.8 | 1202 | 0.197 |
120 | 259 | 0.76 | 1.8 | 1.8 | 25.0 | 1475 | 0.158 |
150 | 320 | 0.76 | 1.8 | 2.2 | 29 | 1911.5 | 0.132 |
185 | 395 | 0.76 | 1.8 | 2.2 | 32 | 2268.65 | 0.108 |
240 | 513 | 0.76 | 2.2 | 3 | 35 | 3010 | 0.0817 |
300 | 641 | 0.76 | 2.4 | 3.5 | 38 | 3770 | 0.0654 |
5. Specification
1) Adopting tinned copper, the conductor meet the requirements of JB 947-76 Copper Conductor for Rubber and Plastic Insulated Cables.
2) The rubber insulation meets the requirements of JB 664-77 Rubber for Wires and Cables. The Min. thickness of insulation shall be no less than the difference of 90% of the nominal thickness and 0.1 mm.
3) The rubber sheath meets the requirements of JB 664-77 Rubber for Wires and Cables. The Min. thickness of insulation shall be no less than 80% of the nominal thickness.
4) The finished cable shall withstand the AC voltage test of 50HZ specified in QYDDL 0118-2003.