Cable in photovoltaic system
Cable implementation specification
he product is designed, manufactured and tested in accordance with the German 2 Pfg 1169/08.2007 technical specification.
TUV certification number and test report number
TUV certification No.: T50344566 01
TUV test report No.: 50042876 001
Product instruction
2 Pfg 1169/08.2007 is suitable for single-core flexible cables (wires) used on the CD side in photovoltaic systems with a maximum allowable 1.8KV (core to core, ungrounded system) DC voltage.
The product is suitable for use in Class II safety levels; cable operating ambient temperatures up to 90 ° C; cables can be used in parallel.
Characteristics
1.Rated voltage
AC: U0/U 0.6/1KV
DC: 1.8KV (wire-conductor, ungrounded system, circuit under non-load conditions).
Maximum allowable working voltage:
AC:0.7/1.2KV AC: 0.7/1.2KV
DC:0.9/1.8KV DC: 0.9/1.8KV
2. Test voltage
AC:6.5KV/5min AC: 6.5KV/5min
DC:15KV/5min DC: 15KV/5min
3. Working temperature
Ambient temperature -40-120 ° C (mobile or fixed)
The maximum temperature during short circuit (within 5 s) does not exceed 200 °C.
4. The cable bend radius is not less than 4 times the cable diameter.
5. The cable insulation and sheathing materials are halogen-free flame retardant crosslinked polyolefin.
6. Cable thermal life 25 years
7. The finished cable has excellent weather resistance, UV and ozone resistance, and can withstand a wide range of temperature changes (from a deep cold -40 ° C to a high temperature 120 ° C mutation).
8. The cable has excellent penetration resistance and meets the technical specifications of TUV2Pfg 1169/08.2007.
Product specifications
Product type | cores | Nominal cross section(mm2) |
PV1-V | 1 | 1.5-16 |
Product structure
Schematic diagram of cable structure for photovoltaic system
Product structure size
Product specifications | Conductor structure
| Conductor outer diameter (mm) | Insulation Thickness (mm) | Sheath Thickness (mm) | Sheath outer diameter (mm) | Weight (kg/km) |
1*1.5 | 30/0.25 | 1.5 | 0.9 | 0.9 | 5.1 | 42 |
1*2.5 | 49/0.25 | 2.0 | 0.9 | 0.9 | 5.6 | 54 |
1*4 | 56/0.3 | 2.5 | 0.9 | 0.9 | 6.1 | 72 |
1*6 | 84/0.3 | 3.5 | 0.9 | 0.9 | 7.1 | 100 |
1*10 | 84/0.4 | 4.5 | 1.0 | 1.0 | 8.5 | 157 |
1*16 | 126/0.4 | 5.6 | 1.0 | 1.0 | 9.6 | 215 |
Cable reference current carrying capacity
Ambient temperature 60 ℃
Conductor temperature 120 ℃
Conductor nominal cross section(mm2) | Single core cable air laying (A) | Laying on the surface of the device (A) | Adjacent to the surface of the device (A) |
1.5 2.5 4 6 10 16 | 30 41 55 70 98 132 | 29 39 52 67 93 125 | 24 33 44 57 79 107 |