Twist resistant cable for wind power generation with rated voltage of 1.8/3KV and below
Usage
It is suitable for torsion-resistant flexible cables for wind power generation with rated voltages of 1.8/3KV and below in impellers and fixed installation towers for wind power generation equipment or other similar occasions.
Use characteristics
The rated voltage U0/U of the cable is 450/750V.0.6/1KV.1.8/3KV.
The maximum temperature of the conductor (rated cable operating temperature) during normal operation: 70 ° C or 90 ° C.
The minimum bend radius of the cable is six times the diameter of the cable.
The minimum ambient temperature for cable adaptation, common type: -25 ° C; cold type: -40 ° C; more cold type: -55 ° C.
Types and name
Type | Rated Voltage | Names |
FDEF-25 | 450/750V | Copper core ethylene-propylene rubber insulated neoprene rubber sheathed twist-resistant flexible cable for wind power generation |
FDEF-40 | Copper core ethylene-propylene rubber insulated neoprene rubber sheathed cold-resistant and twist-resistant flexible cable for wind power generation | |
FDES-25 | 450/750V 0.6/1KV 1.8/3KV | Copper core Ethylene propylene rubber insulated thermoplastic elastomer sheathed twist resistant flexible cable for wind power generation |
FDES-40 | Copper core ethylene propylene rubber insulated thermoplastic elastomer sheathed cold resistant and twist resistant flexible cable for wind power generation | |
FDES-55 | Copper core ethylene propylene rubber insulated thermoplastic elastomer sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
FDGG-40 | 0.6/1KV 1.8/3KV | Copper core silicone rubber insulated silicon rubber sheathed cold resistant and twist resistant flexible cable for wind power generation |
FDGG-55 | Copper core silicone rubber insulated silicon rubber sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
FDEU-40 | 0.6/1KV 1.8/3KV | Copper core ethylene propylene rubber insulated polyurethane elastomer sheathed cold resistant and twist resistant flexible cable for wind power generation |
FDEU-55 | Copper core ethylene propylene rubber insulated polyurethane elastomer sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
FDEG-40 | 0.6/1KV 1.8/3KV | Copper core Ethylene propylene rubber insulated silicon rubber sheathed cold resistant and twist resistant flexible cable for wind power generation |
FDEG-50 | Copper core Ethylene propylene rubber insulated silicon rubber sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
FDEH-25 | 0.6/1KV 1.8/3KV | Copper core Ethylene propylene rubber insulated chlorosulfonated polyethylene sheathed flexible cable for wind power generation |
FDEH-40 | Copper core ethylene-propylene rubber insulated chlorosulfonated polyethylene sheathed cold-resistant and twist-resistant flexible cable for wind power generation | |
FDEH-55 | Copper core ethylene-propylene rubber insulated chlorosulfonated polyethylene sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
FDGU-40 | 0.6/1KV 1.8/3KV | Copper core silicone rubber insulated polyurethane elastomer sheath cold resistant and twist resistant flexible cable for wind power generation |
FDGU-55 | Copper core silicone rubber insulated polyurethane elastomer sheathed more cold resistant and twist resistant flexible cable for wind power generation | |
FDEPJ-40 | 0.6/1KV 1.8/3KV | Copper core ethylene-propylene rubber insulated low-smoke and halogen-free sheathed cold-resistant and twist-resistant flexible cable for wind power generation |
FDEPJ-55 | Copper core ethylene-propylene rubber insulated low-smoke halogen-free sheathed more cold-resistant and twist-resistant flexible cable for wind power generation | |
Flame-retardant C-type cable with "ZC" in front of the model, metal-shielded cable with "P" after the sheath code |
Specifications
Rated voltage | Cores | Conductor Nominal cross section mm2 |
450/750V 0.6/1KV | 1 | 1.5-400 |
2 | 1-25 | |
3 | 1-300 | |
3+1 | 4-185 | |
4 | 1-300 | |
5 | 1-25 | |
6-36 | 1.5-4 | |
1.8/3kv | 1 | 10-400 |
3 | 10-240 |
Insulating mixture
The insulating material shall be one of the extruded solid media listed in the table below.
Insulating mixture | Code | Maximum conductor temperature | |
Normal operation | Short circuit (maximum 5s) | ||
90 ° C ethylene propylene rubber or other equivalent synthetic elastomer | EPR | 90 | 250 |
Silicone rubber or other equivalent synthetic elastomer | G | 90 | 250 |
The jacket material shall be one of the extruded solid media listed in the following table. The jacket material shall be compatible with the working temperature grade of the insulating material, and the multi-core cable sheath shall not be bonded to the insulation.
Sheath mixture | Code | ℃Long-term allowable operating temperature °C |
Neoprene mixture or other equivalent synthetic elastomer | SEI | 70 |
Chlorosulfonated vinyl chloride or other equivalent synthetic elastomer | SH | 90 |
Silicone rubber or other equivalent synthetic elastomer | G | 90 |
Polyurethane elastomer | TPU | 90 |
Other thermoplastic elastomers | TPV-70 | 70 |
Other thermoplastic elastomers | TPV90 | 90 |
Thermosetting low-smoke halogen-free mixture | PJ | 90 |