CN

New energy cables

Twist resistant cable for wind power generation with rated voltage of 1.8/3KV and below

Twist resistant cable for wind power generation with rated voltage of 1.8/3KV and below

Usage

It is suitable for torsion-resistant flexible cables for wind power generation with rated voltages of 1.8/3KV and below in impellers and fixed installation towers for wind power generation equipment or other similar occasions.

image.png

Use characteristics

The rated voltage U0/U of the cable is 450/750V.0.6/1KV.1.8/3KV.

The maximum temperature of the conductor (rated cable operating temperature) during normal operation: 70 ° C or 90 ° C.

The minimum bend radius of the cable is six times the diameter of the cable.

The minimum ambient temperature for cable adaptation, common type: -25 ° C; cold type: -40 ° C; more cold type: -55 ° C.

Types and name

Type

Rated Voltage

Names

FDEF-25

450/750V

Copper core ethylene-propylene rubber insulated neoprene rubber sheathed twist-resistant flexible cable for wind power generation

FDEF-40

Copper core ethylene-propylene rubber insulated neoprene rubber sheathed cold-resistant and twist-resistant flexible cable for wind power generation

FDES-25

450/750V

0.6/1KV

1.8/3KV

Copper core Ethylene propylene rubber insulated thermoplastic elastomer sheathed twist resistant flexible cable for wind power generation

FDES-40

Copper core ethylene propylene rubber insulated thermoplastic elastomer sheathed cold resistant and twist resistant flexible cable for wind power generation

FDES-55

Copper core ethylene propylene rubber insulated thermoplastic elastomer sheathed more cold-resistant and twist-resistant flexible cable for wind power generation

FDGG-40

0.6/1KV

1.8/3KV

Copper core silicone rubber insulated silicon rubber sheathed cold resistant and twist resistant flexible cable for wind power generation

FDGG-55

Copper core silicone rubber insulated silicon rubber sheathed  more cold-resistant and twist-resistant flexible cable for wind power generation

FDEU-40

0.6/1KV

1.8/3KV

Copper core ethylene propylene rubber insulated polyurethane elastomer sheathed cold resistant and twist resistant flexible cable for wind power generation

FDEU-55

Copper core ethylene propylene rubber insulated polyurethane elastomer sheathed more cold-resistant and twist-resistant flexible cable for wind power generation

FDEG-40

0.6/1KV

1.8/3KV

Copper core Ethylene propylene rubber insulated silicon rubber sheathed cold resistant and twist resistant flexible cable for wind power generation

FDEG-50

Copper core Ethylene propylene rubber insulated silicon rubber sheathed more cold-resistant and twist-resistant flexible cable for wind power generation

FDEH-25

0.6/1KV

1.8/3KV

Copper core Ethylene propylene rubber insulated chlorosulfonated polyethylene sheathed flexible cable for wind power generation

FDEH-40

Copper core ethylene-propylene rubber insulated chlorosulfonated polyethylene sheathed cold-resistant and twist-resistant flexible cable for wind power generation

FDEH-55

Copper core ethylene-propylene rubber insulated chlorosulfonated polyethylene sheathed more cold-resistant and twist-resistant flexible cable for wind power generation

FDGU-40

0.6/1KV

1.8/3KV

Copper core silicone rubber insulated polyurethane elastomer sheath cold resistant and twist resistant flexible cable for wind power generation

FDGU-55

Copper core silicone rubber insulated polyurethane elastomer sheathed more cold resistant and twist resistant flexible cable for wind power generation

FDEPJ-40

0.6/1KV

1.8/3KV

Copper core ethylene-propylene rubber insulated low-smoke and halogen-free sheathed cold-resistant and twist-resistant flexible cable for wind power generation

FDEPJ-55

Copper core ethylene-propylene rubber insulated low-smoke halogen-free sheathed more cold-resistant and twist-resistant flexible cable for wind power generation

Flame-retardant C-type cable with "ZC" in front of the model, metal-shielded cable with "P" after the sheath code

Specifications

Rated voltage

Cores

Conductor Nominal cross section mm2

 

 

 

450/750V

0.6/1KV

1

1.5-400

2

1-25

3

1-300

3+1

4-185

4

1-300

5

1-25

6-36

1.5-4

1.8/3kv

1

10-400

3

10-240

Insulating mixture

The insulating material shall be one of the extruded solid media listed in the table below.

Insulating mixture

 Code

Maximum conductor temperature

Normal operation

Short circuit (maximum 5s)

90 ° C ethylene propylene rubber or other equivalent synthetic elastomer

EPR

90

250

Silicone rubber or other equivalent synthetic elastomer

G

90

250

The jacket material shall be one of the extruded solid media listed in the following table. The jacket material shall be compatible with the working temperature grade of the insulating material, and the multi-core cable sheath shall not be bonded to the insulation.

Sheath mixture

Code

℃Long-term allowable operating temperature °C

Neoprene mixture or other equivalent synthetic elastomer

SEI

70

Chlorosulfonated vinyl chloride or other equivalent synthetic elastomer

SH

90

Silicone rubber or other equivalent synthetic elastomer

G

90

Polyurethane elastomer

TPU

90

Other thermoplastic elastomers

TPV-70

70

Other thermoplastic elastomers

TPV90

90

Thermosetting low-smoke halogen-free mixture

PJ

90


Contact us

Add:No.268 jingwu road, economic development zone,
   yueqing city, zhejiang province
Service hotline:400-0700-118  Tel:0577-62667555
Alibaba site:zghongqidianlan.1688.com
© 2013-2018 China · HongQi group LTD. All rights reserved

  • Company website